In power systems, earth-net ground resistance is mainly measured using the power-frequency, high-current method, with test current required to be at least 30 A to reduce grid-frequency interference and improve measurement accuracy. As a result, the test equipment is cumbersome, the procedure is complex, and overall test time is long.

SKU 22
Categories Grounding Connection Device Parameters Tester

In power systems, earth-net ground resistance is mainly measured using the power-frequency, high-current method, with test current required to be at least 30 A to reduce grid-frequency interference and improve measurement accuracy. As a result, the test equipment is cumbersome, the procedure is complex, and overall test time is long.

INSTRUCTION:

At present, in power systems, the earth resistance of the earthing network is mainly tested using the power-frequency, high-current method. To prevent frequency interference caused by grid operation and to improve the accuracy of test results, the testing procedure specifies that the test current for the power-frequency, high-current method must be no less than 30 A. As a result, conventional test equipment is cumbersome, the test process is complex, the test duration is long, and there are other limitations.
HANDY Grounding Connection Device Parameter Tester uses a new type of variable-frequency AC power supply. It abandons the traditional frequency-transformer design, significantly reducing the instrument weight. By applying digital signal processing technology, it avoids 50 Hz frequency interference, allowing measurements to be taken without power interruption and improving test accuracy while greatly simplifying the test procedure.
This instrument is suitable for testing the ground resistance of various types of grounding devices, touch potential, step potential, voltage gradient, and soil resistivity. It supports multiple configurations and can measure grounding grids in substations (reference value: 4 Ω), hydrothermal power plants (reference value: 10 Ω), microwave stations (reference value: 10 Ω), and lightning rods (reference value: 10 Ω).


FEATURES:

1. Accurately measures parameters such as ground impedance, ground resistance, touch potential, step potential, voltage gradient, and soil resistivity, meeting the measurement requirements for conventional earthing-network parameters.
2. The test power supply provides an inter-frequency power output close to the target frequency, making it easy to separate frequency components from interference and enabling reliable measurement of small signals.
3. High test accuracy, suitable for measuring earthing grids with very low ground impedance.
4. The all-electronic non-working frequency transformer design is compact and lightweight, making it easy to carry.
5. The instrument automatically completes power boost control and data measurement calculations. Test time is short and workload is low.
6. Current and voltage waveforms can be stored, and test data can be analyzed using the upper computer software.
7. The LCD screen provides clear display indoors and outdoors for the operating interface and test results.
8. Built-in high-capacity memory stores up to 1,000 sets of data and retains data when the power is turned off.
9. High-speed thermal printer prints test data.
10. Upgrade the instrument software via a USB flash drive.

 

SPECIFICATIONS:

1. Power supply: Three-phase 380 V ±10%, 47–63 Hz; Power: 30 kVA
2. Output voltage: 0–400 V (RMS)
3. Output current: 0–50 A (RMS)
4. Testing time: 30 s
5. Testing power frequency: 42–58 Hz, multi-frequency measurement
6. Measurement range: 0–100 Ω; Resolution: 1 mΩ
7. Measurement accuracy: ±(1% ± 5 mΩ)
8. Anti-jamming capability: The ratio of instrument output signal to interference signal can be maintained steadily and accurately at 1:50.
9. Dimensions: 613 mm × 488 mm × 234 mm
10. Working environment: T: -20–50°C; H ≤ 90% RH