HPD5000B integrates multiple partial discharge detection functions and can use UHF, HFCT, TEV, and air ultrasonic (AE) sensors for partial discharge detection in high-voltage equipment. It supports live inspection of GIS, switchgear, cables, transformers, and other installed equipment.
| SKU | 17 |
| Categories | Partial Discharge Analyzer |
HPD5000B integrates multiple partial discharge detection functions and can use UHF, HFCT, TEV, and air ultrasonic (AE) sensors for partial discharge detection in high-voltage equipment. It supports live inspection of GIS, switchgear, cables, transformers, and other installed equipment.
FEATURES:
1. Ultra-High Frequency (UHF) partial discharge testing.
2. High-Frequency Current Transformer (HFCT) partial discharge testing.
3. Acoustic Emission (AE) partial discharge testing.
4. External surface sticker ultrasonic partial discharge testing.
5. Transient Earth Voltage (TEV) partial discharge testing.
6. Refresh PRPS and PRPD patterns in real time.
7. Equipped with an ultra-high-frequency selective frequency filter, combining high-pass, low-pass, band-stop (900 MHz), and all-pass functions.
8. High-frequency current anti-interference selective frequency filter with multiple combinations.
9. Operable on a 10-inch Windows tablet computer.
10. Built-in high-capacity battery, enabling continuous testing for more than 4 hours.
11. The wireless module uses an aluminum alloy skeleton design to help prevent impact damage.
12. Fully wireless sensor design—no wiring required.
SPECIFICATIONS:
Partial discharge detection parameters:
UHF test bandwidth: 300 to 1500 MHz (reference/typical)
UHF selective frequency filter: high-pass, low-pass, band-stop (900 MHz), all-pass
UHF test sensitivity: -85 dBm (reference/typical)
UHF test dynamic range: 70 dB (reference/typical)
HFCT test bandwidth: 3 to 30 MHz (reference/typical)
HFCT anti-interference filter: 10 MHz, 17 MHz, 24 MHz
HFCT test dynamic range: 80 dB (reference/typical)
TEV coupling bandwidth: 3 to 30 MHz (reference/typical)
TEV resolution: 1 dB (reference/typical)
TEV dynamic range: 80 dB (reference/typical)
Internal AE center frequency: 40 kHz
External surface sticker ultrasonic measurement bandwidth: 20 to 200 kHz (reference/typical)
Ultrasonic measurement dynamic range: 95 dB (reference/typical)
Sensor parameters:
UHF antenna equivalent height: 14 mm
HFCT impedance: ≥12 Ω @(3 to 30 MHz)
AE sensor sensitivity: -67 dB @ 40 kHz
TEV coupling capacitance: 50 pF
Display:
Screen: 10-inch
Brightness: 500 nit
Touch screen: capacitive
Resolution: 1920×1200
Machine:
Tablet computer:
Dimensions: 275×178×18 mm
Weight: 900 g
IP rating: IP67
Wireless module:
Dimensions: 104×70×35 mm
Weight: 250 g
Power supply:
Tablet computer
Battery capacity: 10,500 mAh; built-in lithium battery
Battery life: 4 hours
Wireless module
Battery capacity: 4,000 mAh; built-in lithium battery
Battery life: 6 hours
Environment:
Temperature: -10℃ to 50℃
Humidity: ≤90% RH