LPT1504 Power frequency parameters of Transmission Line Analyzer

  • Home Products
  • LPT1504 Power frequency parameters of Transmission Line Analyzer
LPT1504 Power frequency parameters of Transmission Line Analyzer
  • PB20D Circuit Breaker Control Power Supply
  • PB60D Circuit Breaker Control Power Supply
  • CDF8200A Capacitance and Dissipation Factor (Tan Delta) Tester
  • GI6805 Grounding Connection Device Parameters Tester

LPT1504 Power frequency parameters of Transmission Line Analyzer

Power-frequency parameters of long-distance EHV and UHV transmission lines form the basis for power system modelling and analysis, but accurate measurement is difficult because the lines are reactance-dominated and exposed to strong external interference.

SKU 20
Categories Transmission Line Parameter Testing

Power-frequency parameters of long-distance EHV and UHV transmission lines form the basis for power system modelling and analysis, but accurate measurement is difficult because the lines are reactance-dominated and exposed to strong external interference.

FEATURES

1. Uses a variable method to accurately measure positive-sequence short-circuit impedance, positive-sequence open-circuit impedance (positive-sequence capacitor), zero-sequence short-circuit impedance, and zero-sequence open-circuit impedance (zero-sequence capacitor), as well as the coupling inductor (mutual inductor), coupling capacitor, and induction current.

2. Uses the DC power method to check line phases.

3. Measures line DC resistance and converts the resistance to the specified temperature reference.

4. Measures induction voltage. A voltage divider is required when the induced voltage exceeds 750 V.

5. Built-in Bluetooth for safe operation of the analyzer via a mobile phone or tablet (Option).

6. The analyzer uses an all-in-one design for an electronic non-working frequency transformer, offering a compact size, lightweight build, and convenient carrying.

7. One-time connection enables phase checking, DC resistance measurement, and line parameter testing in a single setup, improving work efficiency and avoiding safety risks caused by repeated reconnections.

8. Hardware and software anti-jamming measures, with anti-frequency interference capability up to 1000 times.

9. Zero-sequence impedance measurement uses a three-phase parallel output mode, providing three times the induction current withstand capability compared with single-phase output mode.

10. No additional anti-jamming suppression device is required. The analyzer can withstand induction current from 10 A to 100 A (different model).

11. Performs boost voltage, measuring, and voltage drop-down automatically, and calculates results, saving testing time.

12. Stores current and voltage curves and analyzes results on a computer.

13. Built-in high-capacity memory stores 1024 sets of data and retains data without power loss.

14. Uses a USB flash drive to transfer test data and upgrade software.

15. Test interface and test data are displayed on the LCD screen, providing clear visibility both indoors and outdoors.

16. High-speed thermal printer outputs test data.

17. Includes input power overvoltage protection (>270 V AC).

18. Includes an ungrounded status prompt function.


TECHNICAL

1. Power supply: single-phase AC 198 to 264 V, 47 to 63 Hz, 5 kVA

2. Output voltage: three-phase, 0 to 200 V (RMS)

3. Output current: three-phase, 0 to 10 A (RMS)

4. Test frequency: 42 to 58 Hz

5. Capacitance measurement range: 0.1 to 30 μF; resolution: 0.01 μF

Accuracy (reference): 0.1 to 1 μF: ±(3% of reading + 0.01 μF); 1 to 50 μF: ±(1% of reading + 0.01 μF)

6. Resistance measurement range: 0.5 to 400 Ω; resolution: 0.01 Ω

Accuracy (reference): 0.5 to 1 Ω: ±(3%Z + 0.01 Ω); 1 to 400 Ω: ±(1%Z + 0.01 Ω)

7. Impedance angle measurement range: 0 to 360°; resolution: 0.01°

Accuracy (reference): ±0.3°

8. DC resistance measurement range: 0.02 to 60 Ω; resolution: 0.1 mΩ

Accuracy (reference): ±(0.2%R + 0.2 mΩ). (The unit outputs current of 2 A to 4 A depending on the resistance.)

9. Voltage measurement range: 10 to 750 V; accuracy: ±(0.5%U + 0.2 V)

10. Current measurement range: 0.5 to 20 A; accuracy: ±(0.5%I + 0.02 A)

11. Withstand induction voltage: < 30 kV

12. Withstand induction current: per phase 40 A; zero sequence 120 A

13. Dimensions: 613 × 488 × 341 mm

14. Weight: 27 kg

15. Environmental conditions: T: -20 to 50°C; H ≤ 90% RH